PERFORMANCE RATINGS - MODELS HD50 & HD80
AMCA LICENSED PERFORMANCE
AMPS
MODEL AMPS
NUMBER
HD50 0.4
HD80 0.5
WEIGHT
MODEL NO. SHIPPING WT.
HD50 7.1 lbs.
HD80 7.2 lbs.
Broan- NuTone LLC certifies
that the models shown herein
are licensed to bear the AMCA
Seal. The ratings shown are
based on tests and procedures
performed in accordance with
AMCA Publication 211 and
AMCA Publication 311 and
comply with the requirements
of the AMCA Certified Ratings
Program.
HVI PERFORMANCE
MODEL NUMBER SONES CFM @0.1'’ Ps
HD50 1.5 50
HD80 2.5 80
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
Model HVI Sones AMCA Sones
Number @ 0.1" Ps* @ 0.0" Ps*
HD50 1.5 1.9
HD80 2.5 4.0
Model Nominal
No. 0.0 0.1 .125 .250 .375 Volts Watts RPM Duct Size
HD50
CFM 61 51 48 31 9
120 30 1070 4" Round
Sones 1.9 2.2 2.3 3.0 3.3
HD80
CFM 93 84 81 65 47
120 50 1380 4" Round
Sones 4.0 4.1 4.1 4.3 4.6
*There is a difference between sone values certified by HVI for residential use
and by AMCA for commercial/industrial use. Exact comparison of these values
is not possible. This difference is mainly due to the procedures used to convert
measured sound to perceived sound. ANSI S3.4, used by both HVI and
AMCA, specifies a procedure for calculating loudness as perceived by a
typical listener under specific conditions. HVI establishes values at a distance
of 5 feet from the fan in a “spherical free field’’; AMCA establishes values at a
distance of 5 feet in a "hemispherical free field". HVI and AMCA have different
rules for rounding sone values.
SONES
Static Pressure (in. wg Ps)
The performance ratings include the effects of inlet grille and backdraft damper in the airstream. Speed (RPM) shown is nominal. Performance is based on actual speed of
test. The sound ratings are loudness values in fan sones at 5' (1.5m) in a hemispherical free field calculated per AMCA Std. 301. Values shown are for Installation Type B: Free
inlet fan sone levels. Air performance shown is for Installation Type B: Free inlet, Ducted outlet.
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
0.55
0.60
0 102030405060708090100
AIR FLOW RATE (CFM)
STATIC PRESSURE (IN. WG)
HD50
HD80
HVI-2100 CERTIFIED RATINGS comply with new
testing technologies and procedures prescribed by
the Home Ventilating Institute, for off-the-shelf
products, as they are available to consumers. Product
performance is rated at 0.1 in. static pressure, based
on tests conducted in AMCA’s state-of-the-art test
laboratory. Sones are a measure of humanly-
perceived loudness, based on laboratory
measurements.